Download Solution PDFWhich type of measurement is not done by Schering bridge?
Answer (Detailed Solution Below)
Detailed Solution
Download Solution PDFThe correct answer is option 4.
Schering bridge is used for the measurement of capacitance and its parameters such as permittivity and dielectric loss.
Measurement of resistance, capacitance, and inductance
Measurement of resistance |
High resistance |
Megger circuit, Loss of charge method |
Medium resistance |
Substitution method, Ohmmeter, Wheatstone bridge |
|
Low resistance |
Kelvin double bridge, Potentiometer, Ammeter-Voltmeter method |
|
Measurement of inductance |
High Q value |
Hay’s bridge |
Medium Q value |
Maxwell Inductance Capacitance bridge |
|
Low Q value |
Owen’s bridge, Anderson bridge |
|
Measurement of capacitance |
Lossy Capacitor |
Schering bridge |
Lossless Capacitor |
De-Sauty’s bridge |