Sampling Theorem and Nyquist Rate MCQ Quiz in தமிழ் - Objective Question with Answer for Sampling Theorem and Nyquist Rate - இலவச PDF ஐப் பதிவிறக்கவும்

Last updated on Mar 14, 2025

பெறு Sampling Theorem and Nyquist Rate பதில்கள் மற்றும் விரிவான தீர்வுகளுடன் கூடிய பல தேர்வு கேள்விகள் (MCQ வினாடிவினா). இவற்றை இலவசமாகப் பதிவிறக்கவும் Sampling Theorem and Nyquist Rate MCQ வினாடி வினா Pdf மற்றும் வங்கி, SSC, ரயில்வே, UPSC, மாநில PSC போன்ற உங்களின் வரவிருக்கும் தேர்வுகளுக்குத் தயாராகுங்கள்.

Latest Sampling Theorem and Nyquist Rate MCQ Objective Questions

Top Sampling Theorem and Nyquist Rate MCQ Objective Questions

Sampling Theorem and Nyquist Rate Question 1:

The signal y(t) is generated by convolving a bandlimited signal x1(t) with another band limited signal x2(t) that is:

y(t) = x1(t) * x2(t)

Where,

X1(ω) = 0 for |ω| > 1000 π

X2(ω) = 0 for |ω| > 2000 π

Impulse train sampling is performed on y(t) to obtain

The value for the sampling period T which ensures such that y(t) is recoverable from yp(t) is ____ milli seconds.

Answer (Detailed Solution Below) 0.95 - 1.05

Sampling Theorem and Nyquist Rate Question 1 Detailed Solution

Concept:

Convolution in time domain is multiplication in frequency domain

y(t) = x1(t) × x2(t)

Y(ω) = X1(ω) X2(ω)

Calculations:

X1(ω) = 0 for |ω| > 1000 π

X2(ω) = 0 for |ω| > 2000 π

Output Y(ω) = X1(ω) X2(ω)

Maximum frequency of Y(ω) = 1000 π radians

Nyquist rate = 2 × 1000 π = 2000 π

Sampling period T

Sampling period T = 1 m sec

Sampling Theorem and Nyquist Rate Question 2:

Let x(t) be continuous time signal with Nyquist rate ω0. The Nyquist rate of signal  is

  1. 0
  2. ω0
  3. ω0/2
  4. None of the above

Answer (Detailed Solution Below)

Option 2 : ω0

Sampling Theorem and Nyquist Rate Question 2 Detailed Solution

Y(jω) = (jω)X (jω)

The message y(t) has same maximum frequency as x(t) with a multiplication factor of jω in the amplitude. 

The bandwidth the signal y(t) will be same as x(t) hence the Nyquist rate is same i.e ω0

Sampling Theorem and Nyquist Rate Question 3:

An input signal  is sampled with a sampling frequency of  and applied to the system whose transfer function is represented by

where,  represents the number of samples per cycle. The output  of the system under steady state is

Answer (Detailed Solution Below)

Option 1 :

Sampling Theorem and Nyquist Rate Question 3 Detailed Solution

Concept:

Final value theorem,

Calculation:

We have:

....(1)

and x(t) = 2 + 5sin(100πt)

sampling frequency, fs = 400 Hz

put t = nTs, the output of the sampling process is,

x(nTs) = 2 + sin(100πnTs)

x(nTs) = 2 + 5 sin

x(nTs) = 2 + 5

where,

ω0 = π/4

The z-transform of x(n) is,

From equation (i)

using final value theorem,

y(∞) = 0

Sampling Theorem and Nyquist Rate Question 4:

The Nyquist sampling rate of x(t) = cos (500 πt) * cos (800 πt) is ______ Hz. (* denotes the convolution operation)

Answer (Detailed Solution Below) 500

Sampling Theorem and Nyquist Rate Question 4 Detailed Solution

x(t) = cos (500 πt) * cos (800 πt)

 

Multiplication exist between the intersection range so

So ωm = 500 π rad / sec

fm = 250 Hz

Nyquist rate = 2fm

= 500 Hz

Sampling Theorem and Nyquist Rate Question 5:

A signal  is given below:  

 is sampled at twice of nyquist sampling frequency. Sampling interval of x(t) is –

  1. 3.33 msec

  2. 5 msec

  3. 2.5 msec

  4. 1.67 msec

Answer (Detailed Solution Below)

Option 4 :

1.67 msec

Sampling Theorem and Nyquist Rate Question 5 Detailed Solution

We know that,

Nyquist sampling freq. of 

Nyquist sampling freq. of 

Hence, Nyquist sampling freq of  is .

Given that x(t) is sampled at twice of Nyquist sampling freq. hence sampling freq. of 

Hence sampling interval 

Sampling Theorem and Nyquist Rate Question 6:

A signal x(t) is multiplied by a rectangular pulse train p(t).

Now: x(t) would be recovered from the product x(t)p(t) by using an ideal low pass filter if X(jω) = 0 for

  1. ω < 2000π

  2. ω > 1000π

  3. ω < 1000π

  4. ω > 2000π 

Answer (Detailed Solution Below)

Option 2 :

ω > 1000π

Sampling Theorem and Nyquist Rate Question 6 Detailed Solution

To avoid aliasing sampling frequency  should be greater that twice the input signal frequency. The sampling frequency . We have time period of sampling signal . Thus, according to sampling theorem 2\omega_m}\). 

2\omega_m}\)

Thus the sampled signal frequency spectrum should be such that its spectrum does not exists for 1000\pi}\)

Sampling Theorem and Nyquist Rate Question 7:

If a 100 Hz sinusoidal signal is sampled at the rates of 140 Hz, 90 Hz, and 30 Hz, then the aliased frequencies correspond to each sampling rate will be respectively:

  1. 180 Hz, 40 Hz, 50 Hz
  2. 30 Hz, 60 Hz, 50 Hz
  3. 40 Hz, 10 Hz, 70 Hz
  4. 60 Hz, 80 Hz, 10 Hz
  5. 40 Hz, 190 Hz, 130 Hz

Answer (Detailed Solution Below)

Option 3 : 40 Hz, 10 Hz, 70 Hz

Sampling Theorem and Nyquist Rate Question 7 Detailed Solution

Concept:

Aliased frequency component is given by:

fa = |fs – fm|

fs = sampling frequency

fm = message signal frequency

Calculation:

For a sampling rate of 140 Hz, since fs > fm:

Aliased Frequency = fs - fm,               

= 140 – 100 = 40 Hz

For a sampling rate of 90 Hz, since fs m:

Aliased Frequency = fm – fs,       

= 100 – 90 = 10 Hz

For a sampling rate of 30 Hz, since fs m:

Aliased Frequency = fm – fs    

= 100 – 30 = 70 Hz

Aliasing is explained with the help of the spectrum as shown:

Sampling Theorem and Nyquist Rate Question 8:

If the signal cos (15 t) is sampled at a sampling interval of Ts and the resulting discrete time signal is periodic with period 4. Then the sampling interval Ts may be:

  1. 1/30
  2. π/30
  3. 1/60
  4. π/60

Answer (Detailed Solution Below)

Option 2 : π/30

Sampling Theorem and Nyquist Rate Question 8 Detailed Solution

Concept:

Discrete signal is periodic if

 is integer

Application

Period:

Sampling interval is Integral multiple of π/30

Sampling Theorem and Nyquist Rate Question 9:

What type of distortion occurs if a signal that contains frequency components up to 15 kHz is sampled using 20 kHz?

  1. Quantization error
  2. Aliasing
  3. Slope Overload
  4. No distortion

Answer (Detailed Solution Below)

Option 2 : Aliasing

Sampling Theorem and Nyquist Rate Question 9 Detailed Solution

Explanation:

Understanding Aliasing in Signal Processing

Definition: Aliasing is a phenomenon that occurs when a signal is sampled at a rate that is insufficient to capture the changes in the signal accurately. Specifically, aliasing happens when the sampling rate is below the Nyquist rate, which is twice the maximum frequency present in the signal. When aliasing occurs, different signals become indistinguishable from each other after sampling, leading to distortion.

Detailed Explanation: In the context of the given problem, a signal contains frequency components up to 15 kHz, and it is sampled using a 20 kHz sampling rate. According to the Nyquist theorem, the sampling rate must be at least twice the maximum frequency present in the signal to avoid aliasing. Therefore, the Nyquist rate for a signal with a maximum frequency of 15 kHz is 30 kHz. Since the given sampling rate of 20 kHz is below this Nyquist rate, aliasing will occur.

When aliasing occurs, the higher frequency components of the signal are "folded" back into the lower frequencies, causing distortion that makes the original signal indistinguishable from its aliased counterpart. This effect results in a loss of information and can significantly degrade the quality of the reconstructed signal.

Illustrative Example: Consider a simple sine wave with a frequency of 15 kHz. If we sample this wave at 20 kHz, the sampling points will not capture the wave's true form accurately. Instead, the samples will represent a different, lower frequency signal, leading to a distorted representation. This misrepresentation can be visualized by plotting the sampled points and observing that the reconstructed signal does not match the original 15 kHz sine wave.

Importance of Proper Sampling: To avoid aliasing, it is crucial to sample signals at a rate that is at least twice the maximum frequency present in the signal. This requirement ensures that the original signal can be accurately reconstructed from the sampled data. In practical applications, engineers often use anti-aliasing filters to remove high-frequency components before sampling, ensuring that the sampled signal adheres to the Nyquist criterion.

Conclusion: In the given problem, the correct answer is option 2 (Aliasing) because the signal with frequency components up to 15 kHz is sampled at a rate of 20 kHz, which is below the Nyquist rate of 30 kHz, leading to aliasing and resulting in distortion.

Important Information:

Let's analyze the other options to understand why they are incorrect:

Quantization error occurs during the process of converting a continuous signal into a discrete digital signal by approximating the signal's amplitude to the nearest value within a finite set of levels. This type of error is related to the precision of the digital representation and is not specifically related to the sampling rate. In the given problem, the primary issue is the sampling rate being too low, leading to aliasing rather than quantization error.

Slope overload is a phenomenon that occurs in delta modulation when the rate of change of the input signal exceeds the ability of the modulator to track it. This results in distortion due to the inability to follow steep slopes in the signal. Slope overload is not related to the sampling rate but to the modulation technique and its parameters. Therefore, it is not applicable to the given problem.

Option 4 suggests that no distortion occurs, which is incorrect. Given that the sampling rate of 20 kHz is below the Nyquist rate for a signal with frequency components up to 15 kHz, aliasing will occur, causing distortion. Thus, this option does not apply to the scenario described in the problem.

  • Option 1: Quantization Error
  • Option 3: Slope Overload
  • Option 4: No Distortion

Sampling Theorem and Nyquist Rate Question 10:

Let x1(t) and x2(t) be two band-limited signals having bandwidth 𝐵 = 4𝜋 × 103 rad/s each. In the figure below, the Nyquist sampling frequency, in rad/s, required to sample y(t), is

  1. 20𝜋 × 103
  2. 40𝜋 × 103 
  3. 8𝜋 × 103
  4. 32𝜋 × 103

Answer (Detailed Solution Below)

Option 4 : 32𝜋 × 103

Sampling Theorem and Nyquist Rate Question 10 Detailed Solution

Given that, x1(t) and x2(t) are two bandlimited signals having bandwidth B = 4π × 103 rad/sec

and y(t) = x2(t)cos(12π × 103t) + x1(t) cos(4π × 103t)

So, Nyquist rate = 2ωmax

= 2[16π × 103]

= 32π × 103 rad/sec

Hot Links: teen patti refer earn teen patti real cash game teen patti king teen patti boss