The diameter of a domestic sewer pipe laid at gradient 1 in 100 is recommended

This question was previously asked in
SSC JE CE Previous Year Paper 13 (Held on 4th March 2017 Evening)
View all SSC JE CE Papers >
  1. 100 mm
  2. 150 mm
  3. 200 mm
  4. 175 mm

Answer (Detailed Solution Below)

Option 2 : 150 mm
Free
Building Materials for All AE/JE Civil Exams Mock Test
17.4 K Users
20 Questions 20 Marks 20 Mins

Detailed Solution

Download Solution PDF

As, per IS 1972 (1983), Clause 4.6.1.2 The approximate gradients which give this velocity for the sizes of pipes likely to be used in building drainage and the corresponding discharges when flowing half-full are as follows:

Dia. of Sewer (mm)

Minimum Gradient

100

1 in 57

150

1 in 100

200

1 in 145

230

1 in 175

250 1 in 195
300 1 in 250
Latest SSC JE CE Updates

Last updated on Jul 1, 2025

-> SSC JE notification 2025 for Civil Engineering has been released on June 30. 

-> Candidates can fill the SSC JE CE application from June 30 to July 21.

-> SSC JE Civil Engineering written exam (CBT-1) will be conducted on 21st to 31st October.

-> The selection process of the candidates for the SSC Junior Engineer post consists of Paper I, Paper II, Document Verification, and Medical Examination.

-> Candidates who will get selected will get a salary range between Rs. 35,400/- to Rs. 1,12,400/-.

-> Candidates must refer to the SSC JE Previous Year Papers and SSC JE Civil Mock Test, SSC JE Electrical Mock Test, and SSC JE Mechanical Mock Test to understand the type of questions coming in the examination.

-> The Staff Selection Commission conducts the SSC JE exam to recruit Junior Engineers in different disciplines under various departments of the Central Government.

Get Free Access Now
Hot Links: teen patti wink teen patti plus teen patti online all teen patti master teen patti refer earn